NUFLO™ Scanner® 2200 EFM QuickStart Mounting Instructions To install the NuFlo Scanner 2200 EFM, perform the following steps: 1. Mount the Scanner to a flat, vertical surface using the brackets, or bolt to a 2-in. pipe using the pole-mount hardware...
More
NUFLO™ Scanner® 2200 EFM QuickStart Mounting Instructions To install the NuFlo Scanner 2200 EFM, perform the following steps: 1. Mount the Scanner to a flat, vertical surface using the brackets, or bolt to a 2-in. pipe using the pole-mount hardware provided. 2. Install process tubing between the orifice run and the manifold, making sure that the upstream pressure tap is connected to the high-pressure manifold port and the downstream pressure tap is connected to the lowpressure manifold port. Slope all piping at least 1-inch per linear foot to avoid trapping liquid. Part No. 30165024, Rev. A Installing the Scanner 2200 EFM 3. Use a suitable compound or tape on all threaded process connections. 4. Position all shutoff and bypass valves so they are accessible from the front of the instrument. 5. Check the manifold for leaks. Important—Due to the weight of the instrument and the potential for vibration in pipeline installations, direct mounting the Scanner 2200 to a manifold is not recomme